  1. Urinal | The Building Code Forum

    Mar 27, 2024 · B occupancy restaurant. 16 males per table 422 CPC. Single occupancy men's restroom. Urinal required? Code location?

  2. Are Urinals Required in Unisex Restrooms? | The Building Code Forum

    Nov 13, 2023 · Not sure if this belongs in the plumbing code forum, but is there a specific section of code that would allow me to remove a urinal from a single user unisex toilet room? My firm and I are …

  3. Minimum Required Size of Non-ADA Toilet Stall

    Nov 25, 2009 · Where do I find the minimum required size of a non-ADA toilet stall? And, what determines how many stalls must meet ADA requirements when you have more than one toilet in a …

  4. Urinal Requirement - The Building Code Forum

    Apr 12, 2021 · If installed, the urinal shall not require a second water closet to be provided for the female." Assuming your restaurant is an A-2 occupancy with OL<50, then hopefully that takes away …

  5. Urinals in Single User Restrooms - The Building Code Forum

    Oct 25, 2009 · There are designers, architects, and engineers providing California single user restrooms without urinals. By Table 422.1, most occupancy's require these...

  6. ICC ANSI - forward approach to urinal | The Building Code Forum

    Oct 17, 2009 · I have another question concerning accessibility - an on site inspection by a state ran agency has stated the following code section in regards to a Men's group restroom with two urinals. …

  7. Door on Accessible Urinal Stall | The Building Code Forum

    Oct 16, 2009 · In this men’s room there are 2 water closets, and one urinal. One of the two water closets is accessible. This is in a public library. There is a 24” door to the urinal. 1) Is this urinal required to …

  8. Restroom Privacy Latches | The Building Code Forum

    Jan 9, 2025 · This section does not apply to family or assisted-use toilet rooms. 405.3.5 Urinal partitions. Exceptions: 1. Urinal partitions shall not be required in a single-occupant or family/assisted-use toilet …

  9. Partitions between fixtures - 2006 IBC & IPC - The Building Code Forum

    Jan 24, 2011 · Examiner said: Now take a look at the urinal screen's size especially the distance from the floor to the bottom and to the top of the urinal screen. Manufacturers do not make the urinal …

  10. Urinal required in a single occupancy toilet for "B" occupancy?

    Aug 16, 2011 · We have a plan checker that is insisting that because the California Plumbing Code table 422.1 indicates that a urinal is required for 1-100 men for a B occupancy that even when a single …